.Measuring Range: 0-1000V
.Testing Voltage: 0.1~1000V
.DCV ACV multimeter funtion
.Insulation resistance test: output voltage:50V(100%~120%),range:0.00~50.0MΩ
resolution ratio:0.01MΩ,accuracy:±(1.5%+5)
output voltage:50V(100%~120%)range:50~200.0MΩ
resolution ratio:1.00MΩaccuracy:±(5%+5)
output voltage:50V(100%~120%)range:0.20~1.0GΩ
resolution ratio:0.01GΩaccuracy:±(10%+5)
output voltage:100V(100%~120%),range:0.00~100MΩ
resolution ratio:0.01MΩaccuracy:±(1.5%+5)
output voltage:100V(100%~120%),range:100~500MΩ
resolution ratio:1.00MΩaccuracy:±(5%+5)
output voltage:100V(100%~120%),range: 0.5~5.0GΩ
resolution ratio:0.01GΩaccuracy:±(10%+5)
output voltage:250V(100%~120%),range:0.00~200MΩ
resolution ratio:0.01MΩaccuracy:±(1.5%+5)
output voltage:250V(100%~120%),range:200~500MΩ
resolution ratio:1.00MΩaccuracy:±(5%+5)
output voltage:250V(100%~120%),range: 1.0~10GΩ
resolution ratio:0.01GΩaccuracy:±(10%+5)
output voltage:500V(100%~120%),range: 0.00~500MΩ
resolution ratio:0.01MΩaccuracy:±(1.5%+5)
output voltage:500V(100%~120%),range: 0.5~1.0GΩ
resolution ratio:0.01GΩaccuracy:±(5%+5)
output voltage:500V(100%~120%),range: 1.0~10GΩ
resolution ratio:0.10GΩaccuracy:±(10%+5)
output voltage:1000V(100%~120%),range: 0.000~1000MΩ
resolution ratio:0.01MΩaccuracy:±(1.5%+5)
output voltage:1000V(100%~120%),range: 1.0~10GΩ
resolution ratio:0.01GΩaccuracy:±(5%+5)
output voltage:1000V(100%~120%),range: 10~30GΩ
resolution ratio:1.00GΩaccuracy:±(10%+5)
output voltage:1000V(100%~120%),range: 30~100GΩ
resolution ratio:1.00GΩaccuracy:±20%
.Insulation resistance test short circuit current
.Power supply:4x 1.5 AA (not including )
.Range: <2.0MA
.Voltage test:Voltage type:ACV ,range :10-600v(50/60hz)
.Resolution ratio:1V,accuracy:±(1.5%+5)Voltage test:
.Voltage type:DCV ,range :0-±600vresolution ratio:1V,accuracy:±(1.5%+5)
.Frequency test range:1~1KHZ
.Resolution ratio:0.1HZ ,accuracy:±(0.1%+3)
.Low resistance test range:0.01~200Ωresolution ratio:0.1Ω ,accuracy:±(2%+5)
.EN61010-1,EN61010-2-033,EN61326,CAT.Ⅲ600V
.Power supply :4*1.5AA(not including )